Abstract
A clinical hypothesis claims that cancer patients treated with immune checkpoint inhibitor (ICI) therapy are at increased risk of developing atherosclerosis. To test this, clinicians use PET/CT imaging together with manual sampling procedures that are labor-intensive, operator-dependent, and hard to reproduce at scale. In this thesis, we develop a fully automated pipeline that replaces manual region-of-interest selection with objective, full-volume extraction of arterial FDG uptake, i.e., we combine deep-learning-based anatomical segmentation with a set of morphological filters designed together with medical experts. We apply it to a longitudinal cohort of 64 ICI-treated patients, each with paired pre- and post-therapy scans, and we test the hypothesis across five complementary filtering methods. In contrast to previous manual studies, including previous work on the same dataset, we find no statistically significant increase in aortic uptake after therapy. However, we find a statistically significant increase in the thyroid gland, a process known and reported in the literature as ICI-induced thyroiditis, indicating that the pipeline still detects real treatment effects, so the null is not just an artifact of a weak method. More generally, our results show the value of reproducible full-volume quantification in cardio-oncology imaging.
Additional Files and Images
Weblinks
BibTeX
@mastersthesis{eseroglou-2026-iic,
title = "Investigating Immune Checkpoint Inhibitor–Induced
Atherosclerosis Using Automated CT–PET Analysis",
author = "Christoforos Eseroglou",
year = "2026",
abstract = "A clinical hypothesis claims that cancer patients treated
with immune checkpoint inhibitor (ICI) therapy are at
increased risk of developing atherosclerosis. To test this,
clinicians use PET/CT imaging together with manual sampling
procedures that are labor-intensive, operator-dependent, and
hard to reproduce at scale. In this thesis, we develop a
fully automated pipeline that replaces manual
region-of-interest selection with objective, full-volume
extraction of arterial FDG uptake, i.e., we combine
deep-learning-based anatomical segmentation with a set of
morphological filters designed together with medical
experts. We apply it to a longitudinal cohort of 64
ICI-treated patients, each with paired pre- and post-therapy
scans, and we test the hypothesis across five complementary
filtering methods. In contrast to previous manual studies,
including previous work on the same dataset, we find no
statistically significant increase in aortic uptake after
therapy. However, we find a statistically significant
increase in the thyroid gland, a process known and reported
in the literature as ICI-induced thyroiditis, indicating
that the pipeline still detects real treatment effects, so
the null is not just an artifact of a weak method. More
generally, our results show the value of reproducible
full-volume quantification in cardio-oncology imaging.",
pages = "90",
address = "Favoritenstrasse 9-11/E193-02, A-1040 Vienna, Austria",
school = "Research Unit of Computer Graphics, Institute of Visual
Computing and Human-Centered Technology, Faculty of
Informatics, TU Wien",
keywords = "PET-CT Analysis, segmentation, machine learning",
URL = "https://www.cg.tuwien.ac.at/research/publications/2026/eseroglou-2026-iic/",
}